Tips for a successful search

Using specific industry keywords and phrases will generate the best results for your search. Generic terms like asphalt, building materials, chemicals, etc. will generate a large number of results.
If you are searching to see if we perform a specific Test Method or Specification, use the  Product Testing Index
Call us anytime 813-621-5777
Validated Products
  • Listee
    • Atlas Roofing Corporation
  • Manufacturer Location
    • Madison, AL
  • Category
    • Roofing Material
  • SubCategory
    • Ventilation
  • Certification(s)
    • FBC (HVHZ) TAS 100(A)
    • ASTM E330

HighPoint Stealth Ridge

HighPoint Stealth Ridge is an attic ridge vent for use with asphalt shingle roof cover. Vents are one-sided and are installed asymmetrically along ridgeline. Vents are injection molded polymer. Vents have approximate length dimension of 4ft and accommodate 9in wide asphalt shingle-over width.

Ratings

FBC (HVHZ) TAS 100(A) (Wind and Wind-Driven Rain)
Product has "passed" the requirements for wind and wind-driven rain resistance as set forth in FBC (HVHZ) TAS 100(A).

ASTM E330 (Wind)
Product has a Design Pressure of -172.5psf when installed with 0.120in x 2-1/2in ring shank roofing nails (ASTM F1667 NL RF S Q - 58 Z) placed in pre-molded fastener locations placed in pre-molded fastener locations and approximately 12in o.c. in between into 15/32in thick APA-rated plywood deck sheathing. Fasteners shall penetrate through sheathing. Ridge cap asphalt shingles shall be installed over vent with 0.120in x 2-1/2in ring shank roofing nails (ASTM F1667 NL RF S Q - 58 Z).